Function • Funcionamiento
Functionnement • Funcionamento



6
6
5
1
english
The condensate flows through the feed
line () into the BEKOMAT unit and ac-
cumulates in the container ().
A capacitive sensor () continuously reg-
isters the liquid level and passes a signal
to the electronic control as soon as the
container is filled.
The pilot valve (4) is then activated and
the diaphragm (5) opens the outlet line
(6) for discharging the condensate.
When the BEKOMAT unit has been
emptied, the outlet line is closed again
quickly and tightly without wasting com-
pressed air.
4
The power LED is lit up green when ope-
rating voltage is being applied.
2
Ready for operation
1
Power on
If the condensate discharge is not func-
tioning properly, the valve will keep open-
ing (about every 2 seconds) so as to clear
the fault automatically, if possible.
Test of valve function and manual
2
drainage:
Press button for approx. 2 se-
conds.
In response to longer pressing, the
valve will keep opening.
Do not use this function for conti-
nuous draining!