Download Print this page

Beko BEKOMAT 31 Instructions For Installation And Operation Manual page 8

Advertisement

Installation • Instalación
Installation • Instalação
8
english
Danger!
Compressed air!
In the case of contact with quickly or
suddenly released compressed air or
in the case of bursting plant compo-
nents there is a risk of serious injury
or death.
Measures:
. Do not exceed the max. operating
pressure (see type plate)!
CAUTION ! Maintenance work must
only be carried out when the device
is not under pressure !
. Only use pressure-proof installati-
on materials!
Feed line (NPT½") must be firmly
fixed. Outlet line: short pressure hose
to pressure-proof pipe. Ensure that
condensate cannot squirt onto persons
or objects.
• Feed pipe () and ball valves () at least
½" inner diameter!
No filters in feed line
Slope in feed line > 1% !
Only use ball valves () with full open
port !
• Operating pressure: min. 12 psig
max. 230 psig
• Short pressure hose (4) !
Please fix the hose.
• For each metre of rising slope (5) in
the outlet line, the required minimum
pressure will increase by 1.5 psig.
The rise of the outlet line must not
exceed 17 feet !
• Lay collecting line (min. ½" ) with 1% of
slope.
• Lead discharge pipe (6) from the top
into collecting line (7).
BEKOMAT 31 stand alone

Advertisement