Hardware Status Codes; Table 4-10 Hardware Status Codes - Hitachi HF-W6500 45/40 Feature Manual

Hide thumbs Also See for HF-W6500 45/40:
Table of Contents

Advertisement

4. CHECKING THE HARDWARE STATUS

4.4.4 Hardware status codes

Table 4-10 shows a list of hardware status codes displayed on the status display digital
LEDs by this function.
No.
Status code
1
2
3
4
5
6
7
8
9
10
11
12
Nos. 7 through 12: Those status codes are displayed for D Model only.
No.10: When the RAID is in a fail status, the system cannot operate normally, and
"4b" may not be displayed.
No.12: This code is displayed if media error is configured to be reported as an error.
If multiple errors occur at the same time, the hardware status code with the highest
priority is displayed.
If multiple errors with the same priority occur at the same time, the hardware status codes
are displayed in the order of detection. That means the last detected hardware status code
is displayed on the status display digital LEDs.

Table 4-10 Hardware Status Codes

Location of failure or anticipated location of failure
11
PS fan failure
12
Front fan failure
13
CPU fan failure
21
The temperature inside the chassis becomes abnormal.
31
A failure is anticipated for the drive on drive bay1.
32
A failure is anticipated for the drive on drive bay2.
41
Drive bay1 is offline.
42
Drive bay2 is offline.
4a
Array configuration error
4b
RAID is in a fail status.
4c
RAID is in an unknown status.
4d
Media error on RAID
4-20
Priority
2
3
4
1

Advertisement

Table of Contents
loading

Table of Contents