2. Replacement of Major Parts
2-1. CLEANING ARM, FELT RING
SET POSITION : Normal
(Removal)
1. Release the two catches (a) of the CLEANING ARM
shown in Fig. 2-1 to remove the CLEANING ARM.
(Installation)
1. Install the CLEANING ARM shown in Fig. 2-1.
2-2. STAY PLATE
SET POSITION : Normal
(Removal)
1. Remove the two screws (a) fastening the STAY
PLATE shown in Fig. 2-2 to remove the STAY PLATE.
(Installation)
1. Install the STAY PLATE shown in Fig. 2-2.
a
a
- 2 -
CLEANING
ARM
a
Fig. 2-1
STAY PLATE
a
Fig. 2-2