Connecting The Relay And Power Lead Connectors - Toro TX 1000 Operator's Manual

Compact tool carrier, 4-in-1 electric/hydraulic bucket
Table of Contents

Advertisement

8.
Tighten the terminal screws and pull on the wires
to ensure that they are securely connected.
9.
Install the wire harness retainer and 2 screws
(Figure
14).
10.
Install the connector top half and screw on the
plug nut securely, at the same time seating the
grommet
(Figure
Figure 15
1. Thread the plug nut onto
the 7-pin connector
11.
Install the hose hold-down plates and spacer
tubes removed in step 2.
Important:
Ensure that the wire harness is
not too taut at the 7-pin connector; give the
harness sufficient slack before tightening
the hold-down plates.
12.
Replace the previously removed screws with 2
longer screws (5/16–18 TPI x 1.75 inches).
Note:
These screws are not supplied with the
attachment.
15).
2. Connector top half
4
Connecting the Relay and
Power Lead Connectors
Parts needed for this procedure:
2
Self-tapping screw
2
Relay
1
Fuse (5 A)
Assembling the Relay Connectors
to the Machine
For Model 22327 with serial numbers prior
to 316000467 and Model 22328 with serial
numbers prior to 316999999
g242272
1.
From the rear of the machine, position the
relay connectors on the lower rear face of the
auxiliary valve bracket and mark the location of
the mounting holes on the bracket.
1. Auxiliary valve bracket
2. Drill a hole (4 mm) here .
2.
Drill holes (2) using a 4 mm drill bit at the marks
made in step 1.
3.
Using the 2 self-tapping screws, install the relay
connectors to the auxiliary valve bracket
16).
11
Figure 16
3. Relay connectors
4. Self-tapping screws
g242413
(Figure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bu-003895Bu-003915Bu-004001

Table of Contents