Air-to-water heat pump / split type r410a/50hz

Advertisement

THERMA V
Split Type
6. Performance Data
6.1 Domestic Hot Water Volume
Water Volume means amount of water that can be tapped with a temperature of 40
been heated up to a indicated temperature.
270
AHUW096A3 [HU091 U43]
AHUW16*A3 [HU16* U33]
AHUW14*A3 [HU14* U33]
260
AHUW12*A3 [HU12* U33]
250
240
230
220
210
200
190
40
Note
It is based on the condition that water inlet temperature is 10 .
For using a higher daily Volume, additional heat up operation by electrical heater are required within 24 hours.
Refer to the Owners or Installation manual for more information.
Heat losses of domestic hot water tank (According to EN 12897 ; XL-profile)
Tank Volume ( )
42
44
Tank temperature [ ˚C]
200
46
48
Heat Lossed (kWh/24h)
DHW Tank Integrated Unit
when the DHW tank has
50
52
1.67
54
11