Download Print this page

LG 5BPU0-02D Engineering Product Data Book page 47

Air-to-water heat pump / split type r410a/50hz

Advertisement

THERMA V
Split Type
2. Specifications
Outdoor Units
Power Supply
Cooling
Operation Range
Heating
(Outdoor Tempera-
Domestic Hot
ture)
Water
Type
Model
Diplacement
Compressor
Capacity
Motor Type
Motor Output
Type
GWP
(Global Warming Potential)
Precharged Amount
Refrigerant
t-CO2 eq.
Chargeless-Pipe Length
Additional Charging Volume
Control
Type
Refrigerant Oil
Charged Volume
Quantity
Heat Exchanger
Specification
s
Type
Fan
Air Flow Rate
Type
Fan Motor
Output
Sound Power Level
Heating
Liquid
Piping Connections
Gas
Piping Length
Outdoor Unit
Piping Level Difference
~ Indoor Unit
Unit
Dimensions
Packed Unit
Unit
Weight
Packed Unit
Power Supply Cable
Wiring Connections
(Included Earth)
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And "Electric characteristics" chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound Level Values are measured at Noise Measuring chamber accordance with standard. Therefore, these values depend on the ambient conditions
and values are normally higher in actual operation.
4. Performances are based on the following conditions :
• Cooling : Inlet/Outlet Water Temp. 23°C/18°C, Outdoor Air Temp. 35°CDB / 24°CWB
• Heating : Inlet/Outlet Water Temp. 30°C/35°C, Outdoor Air Temp. 7°CDB / 6°CWB
• Interconnected Pipe Length is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
5. This product contains Fluorinated greenhouse gases.
6. Sound Performances are based on the following conditions.
• Sound Power Level : Measured according to EN14825.
• Sound Pressure Level : Calculated value according to distance of sound power.
V, Ø, Hz
Min. ~ Max.
°C DB
Min. ~ Max.
°C DB
Min. ~ Max.
°C DB
-
Model x No.
cm³/Rev.
kW
-
Rated
W x No.
-
-
g
-
m
g/m
-
-
cc x No.
EA
Row
EA
Column
EA
Fins per Inch
EA
-
Rated
m³/min x No.
-
W x No.
Rated
dB(A)
Type
-
Outer Dia.
mm(inch)
Type
-
Outer Dia.
mm(inch)
Standard
m
Max.
m
Max.
m
W x H x D
mm
W x H x D
mm
kg
kg
No. x mm²
AHUW146A3 [HU141 U33]
220-240 / 1 / 50
5 ~ 48
-20 ~ 35
-
Hermetic Motor
GPT442MAA x 1
44.2
13.92
BLDC
4,000 x 1
R410A
2,087.5
2,300
4.80
7.5
40
Electronic Expansion Valve
FVC68D
1,300 x 1
2
2
32
14
Propeller
55 x 2
BLDC
124 x 2
66
Flare
Ø 9.52 (3/8)
Flare
Ø 15.88 (5/8)
7.5
50
30
950 x 1,380 x 330
1,140 x 1,462 x 461
94.0
107.0
3 x 6.0 (H07RN-F)
Outdoor unit
AHUW166A3 [HU161 U33]
220-240 / 1 / 50
5 ~ 48
-20 ~ 35
-
Hermetic Motor
GPT442MAA x 1
44.2
13.92
BLDC
4,000 x 1
R410A
2,087.5
2,300
4.80
7.5
40
Electronic Expansion Valve
FVC68D
1,300 x 1
2
2
32
14
Propeller
55 x 2
BLDC
124 x 2
66
Flare
Ø 9.52 (3/8)
Flare
Ø 15.88 (5/8)
7.5
50
30
950 x 1,380 x 330
1,140 x 1,462 x 461
94.0
107.0
3 x 6.0 (H07RN-F)
9

Advertisement

loading

This manual is also suitable for:

5bpu0-02c