LG 5BPU0-02D Engineering Product Data Book page 59

Air-to-water heat pump / split type r410a/50hz

Advertisement

THERMA V
Split Type
6. Performance Data
AHUW148A3 [HU143 U33] + AHNW16606B0 [HN1616T NB0]
LWT 7°C
Outdoor
Temperature
TC
PI
7.43
2.58
20
DB
7.24
3.14
30
DB
7.14
3.42
35
DB
7.05
3.70
40
DB
6.95
3.98
45
DB
AHUW168A3 [HU163 U33] + AHNW16606B0 [HN1616T NB0]
Outdoor
LWT 7°C
Temperature
TC
PI
8.11
2.92
20
DB
7.90
3.56
30
DB
7.79
3.87
35
DB
7.69
4.19
40
DB
45
DB
7.58
4.51
Note
1. DB : Dry bulb temperature( ), LWT : Leaving water temperature( )
2. TC : Total capacity(kW), PI : Power Input(kW)
3. Direct interpolation is permissible. Do not extrapolate.
4. Measuring procedure follows EN-14511.
• Rated values are based on standard conditions, and it can be found on specifications.
• Above table values may not be matched according to installation condition. Except for rated value, the performance is not guaranteed.
• In accordance with the test standard(or nations), the rating will vary slightly.
LWT 10°C
LWT 13°C
TC
PI
TC
PI
8.53
2.60
9.62
2.62
8.31
3.17
9.37
3.19
8.19
3.45
9.25
3.48
8.08
3.73
9.12
3.77
7.97
4.02
8.99
4.05
LWT 10°C
LWT 13°C
TC
PI
TC
PI
9.30
2.95
10.50
2.97
9.06
3.59
10.22
3.62
8.94
3.91
10.09
3.94
8.82
4.23
9.95
4.27
8.70
4.55
9.81
4.59
LWT 15°C
LWT 18°C
TC
PI
TC
PI
10.35
2.64
11.45
2.66
10.08
3.21
11.15
3.24
9.95
3.50
11.00
3.53
9.81
3.79
10.85
3.82
9.68
4.07
10.70
4.11
LWT 15°C
LWT 18°C
TC
PI
TC
PI
11.30
2.99
12.49
3.02
11.00
3.64
12.16
3.67
10.85
3.97
12.00
4.00
10.70
4.29
11.84
4.33
10.56
4.62
11.67
4.66
Outdoor unit
LWT 20°C
LWT 22°C
TC
PI
TC
PI
12.18
2.68
-
-
11.86
3.26
-
-
11.70
3.55
12.40
3.57
11.54
3.84
12.23
3.86
11.38
4.13
12.06
4.16
LWT 20°C
LWT 22°C
TC
PI
TC
PI
13.29
3.03
-
-
12.94
3.69
-
-
12.77
4.02
13.53
4.05
12.59
4.35
13.35
4.38
12.42
4.68
13.16
4.71
21