Philips DL8740 Manual page 27

Hide thumbs Also See for DL8740:
Table of Contents

Advertisement

sures may be necessary, such as re-orienting or re
locating the device.
(b) Over the frequency range 150 kHz to 80 MHz,
field strengths should be less than 3V/m.
Recommended separation distances
between portable and mobile RF com
munications equipment and the ME
equipment or ME system – for ME
equipment and ME systems that are
not life supporting
Recommended separation distances between por
table and mobile RF communications equipment
and the device.
The device is intended for use in an electromagne
tic environment in which radiated RF disturbances
are controlled. The customer or the user of the devi
ce can help prevent electromagnetic interference
by maintaining a minimum distance between porta
ble and mobile RF communications equipment
(transmittters) and the device as recommended be
low, according to the maximum output power of
the communications equipment.
 
Rated ma
ximum out
put power
of transmit
ter (W)
0.01
0.1
1
10
100
For transmitters rated at a maximum output power
not listed above, the recommended separation di
stance d in metres (m) can be estimated using the
equation applicable to the frequency of the trans
mitter, where P is the maximum output power ra
ting of the transmitter in watts (W) according to the
transmitter manufacturer.
NOTE 1 At 80MHz and 800MHz, the separation di
stance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situa
tions. Electromagnetic propagation is affected by
absorption and reflection from structures, objects
and people.
Italiano
Introduction
Congratulations on your purchase and welcome to
Philips! To fully benefit from the support that Phi
lips offers, register your product at www.phi
lips.com/welcome.
Intended use
The product is intended for measuring the tempera
ture of the human body via the ear canal by an in
frared sensor. The device is intended for all ages in
a home environment.
General
This Philips ear thermometer has been developed
for accurate and fast human body temperature
measurements in the ear.
Research indicates that the ear is an ideal site for
taking the body temperature. The body temperatu
re is regulated by the hypothalamus (fig. 2). The hy
pothalamus (1) shares the same blood supply as
the tympanic membrane (2).
Measurement results can be transmitted via
Bluetooth® Smart to the Philips HealthSuite health
app for charting and tracking purposes.
General description (Fig. 1)
1
Protection cap
2 Infrared sensor
3 Probe tip
4 History icon
5 Bluetooth® icon
6 Battery symbol
7 Temperature display
8 Power button
9 Temperature light ring
10 °C/°F selection button
11 Battery compartment
12 Battery cover
Important safety information
Read this important information carefully before
you use the device and save it for future reference.
Warning
- Do not measure the body temperature at the
ear site if the ear is inflamed or infected.
- Keep the device out of the reach of children.
Children may not be able to use it according to
the instructions in this user manual. It is not a
toy.
- Do not throw disposable batteries into fire. Bat
teries may explode.
- Do not put the device in a wet ear canal after
swimming or bathing. This may cause injury to
the ear canal.
- Do not use the device if it is broken or dama
ged. Using a broken or damaged device may
cause injury.
Caution
- Only use the device as described in this user ma
nual. Do not use it for any other purpose.
- The device is not intended as a substitute for
consulting a doctor. Measurement results are
for reference only.
Separation distance according to
frequency of transmitter (m)
150 kHz to
80 MHz
Ö
d = 1.167
P
0.117
0.369
1.167
3.690
11.67
80 MHz
800 MHz
to 800
to 2.5 GHz
MHz
d = 1.167
Ö
d = 1.167
P
P
0.117
0.233
0.369
0.738
1.167
2.333
3.690
7.378
11.67
23.33
Ö