Send Diagnostic Command - Fujitsu Scan Partner 300C Instruction Manual

Table of Contents

Advertisement

(j) Command-specific information bytes: Bytes 8 to B
On this scanner, this field is not supported and is fixed to X'00000000'.
(k) Additional sense code, additional sense code qualifier: Bytes C and D
A combination of these fields specifies detailed information about the error reported in the sense key. This scanner
reports the following information:
(l) Sense-key specific bytes: Bytes F to 11
This field is reserved on this scanner.
(X'00000000' must not be expected.)

4.4.5 SEND DIAGNOSTIC command

The following table shows the normal sequence of the SEND DIAGNOSTIC command when used with this scanner.
Step
1
2
Sense
Additional
Additional
key
sense code
sense code
qualifier
0
O0
2
O0
3
80
3
80
3
80
4
44
4
47
5
20
5
24
5
25
5
26
6
00
B
43
Table 4-14
SEND DIAGNOSTIC command
Bus phase
BUS FREE
Verifies bus free
ARBITRATION ON
Obtains bus-usage right
Table 4-13
Description
00
No-sense
00
Not ready
0l
Jam
02
ADF cover open
03
Document chute empty of paper
00
Abnormal internal target
00
SCSI parity error
00
Invalid command
00
Invalid field in CDB
00
Unsupported logical unit
00
Invalid field in parameter list
00
UNIT ATTENTION
00
Message error
← ← → →
Initiator operation
4-29
Target operation