4.4.7 SET WINDOW command

The following table shows the normal sequence of the SET WINDOW command when used with this scanner.
Step
Bus phase
1
BUS FREE
2
ARBITRATION
3
SELECTION
4
(MESSAGE OUT)
5
COMMAND
6
DATA OUT
7
STATUS
8
MESSAGE IN
9
BUS FREE
4.4.7.1
SET WINDOW command: COMMAND phase (initiator
The SET WINDOW command is used to set a window.
The CDB of this command is shown in the following illustration.
Table 4-16 SET WINDOW command
Initiator operation
Verifies bus free
Obtains bus-usage right
Selects target
Selects logical unit
Specifies SET WINDOW (CDB)
Specifies window data
4-33
← ← → →
Target operation
Drives BSY signal
Sets window
Reports GOOD status
Reports message
(Command Complete)
Release BSY signal
→ target)