Lenovo RackSwitch G8264 Installation Manual page 30

Hide thumbs Also See for RackSwitch G8264:
Table of Contents

Advertisement

Power LEDs
30
G8264 Installation Guide
There is no power switch on the G8264 power modules; the switch powers up when 
power is supplied through the power cord to one or both power supplies.
On the front of the switch, the Power LED on the management panel indicates the 
general status of the power supplies. The LED flashes when only one power cord is 
connected, and is steady when both power cords are connected (see "System Status 
LEDs" on page
22).
Additional LED indicators are located on the rear panel of the switch, on the 
individual power supply modules. The following table describes the power supply 
module LED behavior.
Table 8.
Power supply module status LED behavior
LED
State
! ‐ Service
Amber
Off
OK
Green
Off
~AC
Green
Off
Functional Meaning
Power supply failure.
Power supply is operational.
DC output power is present.
DC output power is OK.
AC power is OK.
No power. Output is disabled, or input 
power is outside operating range.

Advertisement

Table of Contents
loading

Table of Contents