All the attributes are committed to non-volatile memory. Immediately following the write to non-
volatile memory the unit is reset. Note: If you have changed the Ethernet parameters you must
reconnect using the correct network and address settings.
8.3.4.4 Disarm
Step 5 of the installation wizard is the disarm phase.
Figure 50 5.8 GHz and 5.4 GHz Variant - Disarm Installation
Once
Section 8.3.4.3
"Wireless Configuration" is complete pressing the "Disarm Installation
15
Agent" button completes the installation process
and the audible installation tone will be
switched off. If the installer wishes to modify the installation configuration then the 'Back' link
can be used to access the installation wizard steps described above.
After disarming the wireless link the user is presented with a message as shown in
Figure
51.
This message has been obtained when configuring the link with a Region Code where maximum
15
The installation process is completed when both ends of the link are 'disarmed'.