4.4 Climatic zones and performance data

Depending on which climatic zone the product is used in, the product performance differs depending on the climatic
ambient conditions.
Climatic zone
Unit
green
blue
red
The performance data given refer to a moderate climate valid for Europe, large parts of South-East Asia, North and South
Africa, parts of North and South America (climatic zone: blue).
For a dry and / or cool climate (climatic zone: green), the following factor applies:
Performance in climatic zone "blue" x approx. 1.2
For a hot and / or humid climate (tropics, climatic zone: red), the following factor applies:
Performance in climatic zone "blue" x approx. 0.7

4.4.1 Performance data

BEKOMAT
®
Max. compressor
performance
Max. refrigeration dryer
performance
Operating pressure
Ø discharge rate
Max. discharge rate (short-
term)*
* The peak volume can only be achieved if the device is correctly installed according to the installation and operation
manual. If in doubt, a venting line must be installed.
16 | 60
Max. compressor performance
m³/min.
1700
60034
1400
49440
1000
35314
1 bar(g)
2 bar(g)
14.5 psi(g)
29.01 psi(g)
226 l/h
243 l/h
59.70 gal/h
64.19 gal/h
950 l/h
1150 l/h
250.96 gal/h
303.79gal/h
Original installation and operation manual
Max. dryer performance
cfm
m³/min.
3400
2800
2000
16 CO
1700 m³/min
60034 cfm
3400 m³/min
120069 cfm
3 bar(g) ... 4 bar(g)
43.51 psi(g) ... 58.01 psi(g)
263 l/h
69.47 gal/h
1400 l/h
369.84 gal/h
cfm
120069
98881
70629
5 bar(g) ... ≥7 bar(g)
72.52 psi(g) ... ≥101.52 psi(g)
274 l/h
72.38 gal/h
1700 l/h
449.09 gal/h

Advertisement