10D1476 K-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL
Model 10D1476S
Engineering Reference
Design Level
with 50XM Electronics
Liner Material
Ceramic Spool
Meter Size [Inches (mm)]
1/25
(1)
1/12
(2)
1/10
(3)
5/32
(4)
1/4
(6)
3/8
(10)
1/2
(15)
1
(25)
1-1/2 (40)
2
(50)
3
(80)
4
(100)
Flange Standard/Pressure Rating
ANSI Class 150
ANSI Class 300
BS10 Table D
BS10 Table E
BS10 Table F
DIN PN16
DIN PN40
U.S.D.A. Sanitary Tri-Clamp Fittings
Electrode Material
Platinum
Electrode Type
Flush
Flange Material
Flangeless Design
Safety Classification
w/o FM Approval (General Purpose)
FM Approved - Primary Flowmeter & Remote-mounted Signal
Converter: Nonincendive for Class I, Div 2, Gp A, B, C & D;
Electrodes Intrinsically Safe for Class I, Div 1, Gp A, B, C & D;
Outdoor Hazardous Locations, NEMA 4X.
U.S.D.A. Approved Meat & Poultry Equipment (Also certified
for F.D.A. & 3A Sanitary Applications)