ABB K-MAG 10D1476 Instruction Manual page 25

Magnetic flowmeters
Hide thumbs Also See for K-MAG 10D1476:
Table of Contents

Advertisement

10D1476 K-MAG MAGNETIC FLOWMETER INSTRUCTION MANUAL
FIGURE 2-6. FLANGE BOLT
TIGHTENING SEQUENCE
The recommended bolt torque limits are based on the use of gas-
kets supplied by the manufacturer. If other than these gaskets are
used, the bolt torques must be adjusted accordingly to prevent
Should it become necessary to replace an existing magnetic flowmeter (that has a longer lay length)
with a Model 10D1476 K-MAG, a flanged spool piece is available from the factory for ANSI Class 150
flanges in
- 4 inch sizes. The length of the spool is selected so that the lay length of the K-MAG
1
25
plus the spool piece will be the same as that of the meter it is replacing. Existing piping does not have
to be altered. Specify the model number and size of the meter being replaced to facilitate pipe spool
selection.
All 1 - 15 mm (
TABLE 2-1. RECOMMENDED BOLT TORQUE
Meter Size
mm (inch)
1 - 25
(
- 1)
1
25
40
(1
)
1
2
50
(2)
80
(3)
100
(4)
NOTE
cracking the spool.
NOTE
-
inch) size magnetic flowmeters are sized to
1
1
25
2
mate with 15 mm (
inch) pipe flanges.
1
2
ANSI CL 150
ANSI CL 300 DIN PN 40
DIN PN 16
BS TABLE D & F
10 ft lb
15 ft lb
15 N • m
20 N • m
15 ft lb
25 ft lb
20 N • m
35 N • m
25 ft lb
15 ft lb
35 N • m
20 N • m
40 ft lb
30ft lb
55 N • m
40 N • m
30 ft lb
-------
40 N • m
Recommended Procedure:
1st Pass - 50% of Torque Value
2nd Pass - 80% of Torque Value
3rd Pass - 100% of Torque Value
BS TABLE F
15 ft lb
20 N • m
40 ft lb
54 N • m
30 ft lb
40 N • m
30 ft lb
40 N • m
-------
2-9