Catalytic converter for removing oil from compressed air
Table of Contents

Advertisement

®
Installation and Operation Manual BEKOKAT
The current supply to the heaters is interrupted as soon as the set limit of 235°C is reached.
It does not matter whether the exceeded temperature was detected in the upper or lower area
of the container.
As soon as the temperature drops below +230°C, the current supply for the heaters is released
again.
In some cases, the threshold may also be slightly lower, e.g. be set to + 200 °C.
Pressing the SET button displays the set limit.
®
The factory-set parameters ensure trouble-free operation of the BEKOKAT
plant. Changing
the setting is not required and may only be performed by authorised skilled technical personnel.
V01 /11-046
37 / 88