Bekokat With Bypass - Beko BEKOKAT CC-360 Installation And Operation Manual

Catalytic converter for removing oil from compressed air
Table of Contents

Advertisement

Installation and Operation Manual BEKOKAT
4.4.2
BEKOKAT
®
®
BEKOKAT
CC-360
Bypass with automatic valve
Prefilter CLEARPOINT M018SWT
Activated carbon filter CLEARPOINT M018AWM
NOTE
Installation
 Please note that the activated carbon filter in the bypass only has a
service life of approx. 100 operating hours.
 In the installation after the BEKOKAT
grease-free models. Otherwise, the system will be contaminated with
hydrocarbons again.
 The maximum permissible pressure of the converter is 16 bar.
 The ambient temperature must be between + 5 °C and + 45 °C.
46 / 88
with Bypass
®
®
, only use components in oil and
V01 /11-046

Advertisement

Table of Contents
loading

Table of Contents