6.3
Reactor temperature> + 60 °C
Malfunction image
The reactor temperature drops below T <+ 60 °C during operation.
Close valves V1 / V2 as complete catalysis can not be ensured. The compressed air
supply is interrupted.
As soon as the valves close, the potential-free alarm contact is activated, signalling the fault
by means of an external display (warning signal, indicator light, etc.). This connection option
must be used.
Cause
The heating system has failed.
The supplied air flow is too large (overload)
and is not heated.
70 / 88
®
Measure
Check the function of the heating elements.
Check volume flow rate.