RU Hardware Feature
RU Specifications
Table 6 (Cont.)
Specification In 3GPP 38.113
Phenomenon
Electrostatic discharge
Fast transients common mode
RF common mode 0, 15...80 MHz
Surges, common and differential
mode
Radiated Immunity
3GPP 38.113
Test Standard
IEC 61000-4-3 Level 3
Traffic mode, excludes receiver exclusion band.
Test mode
3 V/m, AM 80%
80...6000 MHz
A
Performance Criteria
Electric Discharge
3GPP 38.113
Test standard
IEC 61000-4-2
±4 kV
Contact discharge
±8 kV
Air discharge
B
Performance Criteria
Fast Transients Common Mode
3GPP 38.113
Test standard
IEC 61000-4-4
0.5 kV
B
Performance criteria
Power consistency, RET consistency
Injected port
·
Issue 1.1, May 2021
Release 1.0
Application
Enclosure
Signal, telecommunications and
control ports, DC power input
ports
Signal, telecommunications and
control ports, DC power input
ports
AC power input ports,
telecommunications port
Detail
Reference Standard
Specification
IEC 61000-4-2
Electric Discharge
IEC 61000-4-4
Fast Transients
Common Mode
IEC 61000-4-6
RF Common Mode
IEC 61000-4-5
Resistability of
Lightning
26
Criteria
B
B
A
B
Fujitsu and Fujitsu Customer Use Only