Cleaner Solenoid Replacement & Adjustment - Panasonic AJ-SD93P/E Service Manual

Digital video cassette recorder
Table of Contents

Advertisement

<A/C Head Adjustment>
1.
After changing the A/C Head, please perform the
following steps.
3-14. A/C Head Tilt Adjustment
3-15. A/C Head Height Adjustment
3-18. A/C Head Azimuth & X-value Adjustment
NOTE: PG Shifter Adjustment
3-29. to 3-38. LISTA Adjustment
3-39. Self Rec/Play Envelope
Waveform Confirmation
NOTE: CUE AUDIO Adjustment
NOTE:
PG Shifter and CUE AUDIO adjustment procedures
are
mentioned
on
Procedures on Service Manual.
START
END
Electrical
Adjustment
5-22. Cleaner Solenoid
Replacement & Adjustment
(Removal)
1.
Disconnect the P48 on the MECH I/F.
2.
Unscrew the 2 screws (A) and remove the
Cleaner Solenoid Unit as shown in Figure 5-22-1.
3.
Unscrew the 2 screws (B) and remove the
Cleaner Solenoid as shown in Figure 5-22-1.
(Installation)
1.
Install the new Cleaner Solenoid following the
removal steps in reverse order.
2.
After installation, perform the Cleaner Solenoid
Position adjustment.
MECH-55
Figure 5-22-1

Advertisement