Installing the Device
2.4 Connecting the Failsafe Alarm Relay
To mount the device to a panel, do the following:
1.
Place the device against the panel and mark the mounting holes on the panel.
Figure 2.3
2.
Prepare the mounting holes
3.
Align the device with the mounting holes and secure it to the panel.
2.4

Connecting the Failsafe Alarm Relay

The failsafe relay can be configured to latch based on alarm conditions. The NO
(Normally Open) contact is closed when the unit is powered and there are no ac-
tive alarms. If the device is not powered or if an active alarm is configured, the relay
opens the NO contact and closes the NC (Normally Closed) contact.
Note
Control of the failsafe relay output is configurable through RUGGEDCOM RX1501 .
One common application for this relay is to signal an alarm if a power failure occurs.
For more information, refer to the RUGGEDCOM ROX Configuration Manual for the
RUGGEDCOM RX1501.
The following shows the proper relay connections.
10
All manuals and user guides at all-guides.com
1
1
Screw
1
Panel/DIN Rail Adapter
2
Panel Mounting
2
RUGGEDCOM RX1501
Installation Manual, 05/2020, C79000-G8976-1054-17