2.
Loosen the screws that secure the module to the chassis until the module can be
removed.
Figure 4.5
3.
Slide the module out of the chassis.
4.
Disconnect the power supply wiring from the terminal block. Alternatively, for
convenience, remove the terminal block with the wiring still connected and set
it aside to be connected later to the new module.
5.
Install a new or blank module to prevent the ingress of dust and dirt.
Installing a Power Module
To install a power module, do the following:
1.
If equipped, remove the existing module.
2.
If applicable, connect the supplied terminal block to the module or connect the
terminal block from the previous module.
3.
Confirm or connect the wiring from the power supply to the module. For more
information, refer to
RUGGEDCOM RX1501
Installation Manual, 05/2020, C79000-G8976-1054-17
All manuals and user guides at all-guides.com
1
2
3
Chassis
1
Power Supply
2
Screws
3
Removing a Power Supply
"Connecting Power (Page
4.4 Installing/Removing Power Modules
11)".
Modules