Beko BEHPI 090 User Manual page 23

Split-type room air conditioner
Hide thumbs Also See for BEHPI 090:
Table of Contents

Advertisement

Available languages

Available languages

5
Troubleshoot ng
Problem
The un t starts and
stops frequently
Poor heat ng
performance
Ind cator lamps
cont nue flash ng
Error code appears n
the w ndow d splay
of ndoor un t:
• E0, E1, E2...
• P1, P2, P3...
• F1, F2, F3...
C
Note: If your problem persists after performing the checks and diagnostics above, turn off
your unit immediately and contact an authorized service center.
Spl t-type room a r cond t oner / User Manual
Poss ble causes
There's too much or too l ttle
refr gerant n the system
Incompress ble gas or mo sture
has entered the system.
The compressor s broken
The voltage s too h gh or too low
The outdoor temperature s
exetremtly low
Cold a r s enter ng through doors
and w ndows
Low refr gerant due to leak or
long-term use
The un t may stop operat on or cont nue to run safely. If the nd cator
lamps cont nue to flash or error codes appear, wa t for about
10 m nutes. The problem may resolve tself.
If not, d sconnect the power, then connect t aga n. Turn the un t on.
If the problem pers sts, d sconnect the power and contact your nearest
customer serv ce center.
solut on
Check for leaks and recharge the
system w th refr gerant.
Evacuate and recharge the system
w th refr gerant
Replace the compressor
Install a manostat to regulate the
voltage
Use aux l ary heat ng dev ce
Make sure that all doors and
w ndows are closed dur ng use
Check for leaks, re-seal f
necessary and top off refr gerant
23 / 28 EN