Download Print this page

Haier YR-E20 Operation & Installation Manual page 27

Wired controller

Advertisement

(2) After powering on, press function key to shift swing blade
and the following circulation: four-way simultaneous
control→four-way cassette1→four-way cassette2→four-
way cassette3→four-way cassette4→four-way cassette
simultaneous control. If it is not the initial entering, press
function key to display the last swing blade position and
flashing, and it will display the last setting swing angle of
this swing blade on the right-side up/down swing.
(3) When pressing function key to select swing type, the
selected blade will flashing, press up/down key to
adjust swing angle. If pressing mode or fan key in the
adjustment, it will quit four-way cassette adjustment
and display the last set swing blade position and angle.
If there is no operation of up/down key for 5s after
pressing function key, the selected swing blade will stop
flashing and return to the previous state.
3. Swing angle
1
2
3
4
5
6
(1) 1: Position 1 2: Position 2
5: Position 5 6: Position 6(reserved)
(2) The swing angle circulation is: position1→Position
2→Position 3→Position 4→Position 5→Auto→Position1
(3) Auto wind: it will display in circulation:
1→2→3→4→5→4→3→2→1
3: Position 3 4: Position 4
26

Advertisement

loading