Husqvarna BG 250 Operator's Manual page 50

Table of Contents

Advertisement

Available languages

Available languages

3. Loosen the 4 nuts (A) and the 3 screws (B).
4. Remove the 2 screws and the 2 washers (C) and
remove the front cover (D).
5. Loosen the locknut.
6. Remove the V-belt.
50
D
A
B
C
7. Remove the pulleys and the clamp bushing from the
grinding motor and the bearing unit.
8. Install in the opposite sequence. Install the pulley
and the clamp bushing aligned with the motor axle.
Tighten the clamp bushing to a torque of 20 Nm +
10%.
To do a check of the oil level (BG
250Petrol)
CAUTION:
a low oil level can cause damage to the
engine.
1. Stop the engine. Refer to
250Petrol on page 47 .
2. Put the product on level ground.
3. Remove the oil tank cap.
4. Clean the oil from the dipstick that is attached to the
oil tank cap.
5. Put the dipstick in the oil tank. Do not tighten it.
To operate the product with
To stop the product BG
1802 - 002 - 13.04.2022

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bg 250petrol