Toshiba TEC EO1-32003 Owner's Manual page 57

Electronic computing scale
Table of Contents

Advertisement

10. PROGRAMMING PROCEDURES
(1) An error occurs unless the following conditions are met.
① The X value (X point value plus print area's X point value) must not exceed 448 dots
on the 57-mm wide labels, and 632 dots on the 80-mm wide labels.
② The Y value (Y point value plus print area's Y point value) must not exceed 1560
dots (195mm) on the 57-mm wide labels, and 1080 dots (135mm) on the 80-mm
wide labels.
(2) The area size is magnified (x2) for items to be magnified.
(3) Safe handling instructions
Normal type: 384 (W) x 194 (H) dots (same as the ingredients of 13 lines)
Wide type: 592 (W) x 120 (H) dots (same as the ingredients of 8 lines)
(4) FSP block
FSP print format can be programmed easily with FSP block. All of FSP print items
are moved together as one block since FSP block is set "on" status to PRT condition.
In this case each of FSP print items cannot be moved by itself until satus is "off".
10-35
10.21 FREE FORMAT SETTING

Advertisement

Table of Contents
loading