15. ERROR MESSAGE TABLE

15. ERROR MESSAGE TABLE
Take the following action if an error message appears on the commodity name display along with the
buzzer sounding.
If you cannot solve the problem with the following solution instruction, do not attempt further
troubleshooting by yourself. Turn the power off, unplug the scale, then contact your Authorized
Service representative for assistance.
Do not attempt to repair or adjust alone, because electrical equipment is dangerous.
Programming Mode
Message
DATA ENTRY ERROR
MEMORY FULL
DUPLICATE PLU
PLU NOT FOUND
CHARACTER OVERRUN
PRT FAILURE DETECTED Printer trouble.
LABEL OVERRUN
RESTORE THE PLUS
WARNING!
Cause
Error in key input.
No memory space to set PLU.
The PLU # being changed is
already registered.
The PLU # being called is not
registered.
Attempt is made to set more
than max. allowed number of
characters.
Label overruns.
The capacity of RAM was
changed with the ingredient
data stored.
15- 1
15. ERROR MESSAGE TABLE
Solution
CLEAR
Press the
key, and re-input the
right data.
CLEAR
Press the
key, and delete
unnecessary PLUs.
CLEAR
Press the
key, and check the
PLU.
CLEAR
Press the
key, and set the data to
free PLU#.
CLEAR
Press the
key, and re-input the
right data.
1. Check that the media and print head
are set correctly.
2. If the label home position is misaligned,
FEED
press the
key.
FEED
Press the
key.
Press the
CLEAR
key and save the
ingredient data. Then delete the data from
the memory of the unit. After that change
the capacity of RAM and load the data to
the unit.