Chapter 3 Starting Up
3.16 Powering On for the First Time
Power on the equipment within the temperature range in the prescribed temperature conditions. For
details on the operating environment, see
equipment within the prescribed temperature range may lead to malfunctions or loss of data. Fujitsu
is not responsible for any damage or failure caused by use of the equipment outside the temperature
range for guaranteed operation.
3.16.1

AC Power On

The green BMC ready LED blinks (see
connected to the main power supply.
Approximately 240 seconds are required until the node can be powered on. The BMC ready LED stays on
and does not blink when the node can be powered on.
3.16.2

Initial BMC Settings

After confirming that the BMC ready LED has stayed on, make initial settings from the BMC Web GUI. For
details on browser and other settings, see "Chapter 1 Environment and Settings for Using the Web GUI"
in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's Guide (C120-0091EN).
Logging in to the BMC
For details on how to log in to the BMC, see "2.1.1 Login" in the FUJITSU Supercomputer PRIMEHPC
FX700 BMC User's Guide (C120-0091EN).
Setting the Time
To set the BMC time, select [Time Settings] from the [Configuration] menu. For details, see "3.4.4 Time
Settings" in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's Guide (C120-0091EN).
Configuring the Network
To configure the network to use the BMC, select [Network Settings] from the [Configuration] menu. For
details, see "3.4.3 Network Settings" in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's
Guide (C120-0091EN).
Configuring SNMP Traps
To configure SNMP traps, select [SNMP Trap Settings] from the [Configuration] menu. For details, see
"3.4.5 SNMP Trap Settings" in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's Guide
(C120-0091EN).
Setting the Altitude
To set the altitude, select [Chassis Settings] from the [Configuration] menu. For details, see "3.4.1
Chassis Settings" in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's Guide (C120-0091EN).
Powering On
To power on, select [Power On All] from [Node Power Control] in the [Power Control] menu. For details,
see "3.3 Power Control" in the FUJITSU Supercomputer PRIMEHPC FX700 BMC User's Guide
(C120-0091EN).
"3.2 Installation
"Figure 1.11 Front Panel
51
Specifications." Failure to operate the
LEDs") when the equipment is