Parameter list
Setting
Pr.
Name
495
Remote output selection 0, 1, 10, 11
496
Remote output data 1
0 to 4095
497
Remote output data 2
0 to 4095
PLC function flash
0, 9696
498
memory clear
(0 to 9999)
Stop mode selection at
502
0 to 4
communication error
503
Maintenance timer 1
0(1 to 9998)
Maintenance timer 1
0 to 9998,
504
warning output set time
9999
505
Speed setting reference 1 to 590Hz
Emergency drive
0.1 to 600s,
514
dedicated retry waiting
9999
time
Emergency drive
515
1 to 200, 9999 1
dedicated retry count
522
Output stop frequency
0 to 590Hz, 9999 9999
100, 111, 112,
121, 122, 123,
124, 200, 211,
212, 221, 222,
Emergency drive mode
223, 224, 300,
523
selection
311, 312, 321,
322, 323, 324,
400, 411, 412,
421, 422, 423,
424, 9999
0 to 590Hz/
Emergency drive
524
0 to 100%,
running speed
9999
Frequency command
541
0, 1
sign selection
0, 1, 12, 14, 18,
CC-Link extended
544
24, 28, 100, 112,
setting
114, 118, 128
USB communication
547
0 to 31
station number
USB communication
0 to 999.8s,
548
check time interval
9999
NET mode operation
550
command source
0, 1, 5, 9999
selection
PU mode operation
551
command source
1 to 3, 5, 9999 9999
selection
552
Frequency jump range 0 to 30Hz, 9999 9999
553
PID deviation limit
0 to 100%, 9999 9999
PID signal operation
554
0 to 7, 10 to 17 0
selection
555
Current average time
0.1 to 1.0s
556
Data output mask time 0 to 20s
0 to 500A
Current average value
557
monitor signal output
reference current
0 to 3600A
Second frequency
0 to 32767,
560
search gain
9999
PTC thermistor
0.5 to 30kΩ,
561
protection level
9999
Energization time
563
(0 to 65535)
carrying-over times
Operating time
564
(0 to 65535)
carrying-over times
Second motor excitation
0 to 400Hz,
565
current break point
9999
Second motor
0 to 300%,
566
excitation current low-
9999
speed scaling factor
Second motor speed
0 to 200%,
569
control gain
9999
570
Multiple rating setting
0, 1
571
Holding time at a start
0 to 10s, 9999 9999
4 mA input check
573
1 to 4, 9999
selection
Second motor online
574
0, 1
auto tuning
Output interruption
0 to 3600s,
575
detection time
9999
Output interruption
576
0 to 590Hz
detection level
Output interruption
577
900 to 1100% 1000%
cancel level
Auxiliary motor
578
0 to 3
operation selection
Motor connection
579
0 to 3
function selection
MC switchover interlock
580
0 to 100s
time (multi-pump)
Start waiting time (multi-
581
0 to 100s
pump)
Auxiliary motor
0 to 3600s,
582
connection-time
9999
deceleration time
Auxiliary motor
0 to 3600s,
583
disconnection-time
9999
acceleration time
Auxiliary motor 1
584
0 to 590Hz
starting frequency
20
BASIC OPERATION
Initial
Pr.
range
value
0
Auxiliary motor 2
585
starting frequency
0
Auxiliary motor 3
0
586
starting frequency
0
Auxiliary motor 1
587
stopping frequency
0
Auxiliary motor 2
588
stopping frequency
0
Auxiliary motor 3
589
stopping frequency
9999
Auxiliary motor start
590
60/50Hz

detection time
Auxiliary motor stop
591
9999
detection time
Traverse function
592
selection
Maximum amplitude
593
amount
Amplitude
594
compensation amount
during deceleration
Amplitude
9999
595
compensation amount
during acceleration
Amplitude acceleration
596
time
Amplitude deceleration
597
time
9999
598
Undervoltage level
0
X10 terminal input
599
0
selection
First free thermal
600
reduction frequency 1
0
First free thermal
601
reduction ratio 1
9999
First free thermal
602
reduction frequency 2
9999
First free thermal
603
reduction ratio 2
First free thermal
604
reduction frequency 3
Power failure stop external
606
signal input selection
Motor permissible load
607
level
Second motor
608
1s
permissible load level
0s
PID set point/deviation
609
input selection
Inverter

PID measured value
LD/SLD
610
input selection
rated

current

Acceleration time at a
611
restart
9999
Reverse rotation
617
excitation current low-
9999
speed scaling factor
653
Speed smoothing control 0 to 200%
0
Speed smoothing cutoff
654
frequency
0
Analog remote output
655
selection
9999
656
Analog remote output 1
657
Analog remote output 2
9999
658
Analog remote output 3
659
Analog remote output 4
9999
Increased magnetic
660
excitation deceleration
1/0

operation selection
Magnetic excitation
661
increase rate
9999
Increased magnetic
662
excitation current level 0 to 300%
0
Control circuit temperature
663
signal output level
1s
Regeneration avoidance
665
frequency gain
0Hz
Power failure stop
668
frequency gain
SF-PR slip amount
673
adjustment operation
0
selection
SF-PR slip amount
0
674
adjustment gain
Tuning data unit
1s
684
switchover
686
Maintenance timer 2
1s
Maintenance timer 2
687
warning output set time
1s
688
Maintenance timer 3
Maintenance timer 3
689
warning output set time
1s
Second free thermal
692
reduction frequency 1
60/50Hz

Setting
Initial
Name
range
value
0 to 590Hz
60/50Hz
0 to 590Hz
60/50Hz
0 to 590Hz
0Hz
0 to 590Hz
0Hz
0 to 590Hz
0Hz
0 to 3600s
5s
0 to 3600s
5s
0 to 2
0
0 to 25%
10%
0 to 50%
10%
0 to 50%
10%
0.1 to 3600s
5s
0.1 to 3600s
5s
175 to 215V,
9999/
9999
350 to 430V,
9999

0,1
0
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
0, 1
1
110 to 250%
150%
110 to 250%,
9999
9999
1 to 5
2
1 to 5, 101 to
3
105
0 to 3600s,
9999
9999
0 to 300%,
9999
9999
0
0 to 120Hz
20Hz
0, 1, 10, 11
0
1000%
1000%
800 to 1200%
1000%
1000%
0, 1
0
0 to 40%, 9999 9999
100%
0 to 100°C
0°C
0 to 200%
100%
0 to 200%
100%
2, 4, 6, 9999
9999
0 to 500%
100%
0, 1
0
0(1 to 9998)
0
0 to 9998,
9999
9999
0(1 to 9998)
0
0 to 9998,
9999
9999
0 to 590Hz,
9999
9999
Pr.
Name
Second free thermal
693
1 to 100%

reduction ratio 1
Second free thermal
0 to 590Hz,
694

reduction frequency 2
9999
Second free thermal
695
1 to 100%
reduction ratio 2
Second free thermal
0 to 590Hz,
696
reduction frequency 3
9999
5 to 50ms,
699
Input terminal filter
9999
702
Maximum motor frequency 0 to 400Hz, 9999 9999
Induced voltage
0 to 5000mV/
706
constant (phi f)
(rad/s), 9999
707
Motor inertia (integer)
10 to 999, 9999 9999
711
Motor Ld decay ratio
0 to 100%, 9999 9999
712
Motor Lq decay ratio
0 to 100%, 9999 9999
Starting resistance
0 to 200%,
717
tuning compensation
9999
Starting magnetic pole
0 to 6000μs,
721
position detection pulse
10000 to
width
16000μs, 9999
724
Motor inertia (exponent) 0 to 7, 9999
Motor protection current
100 to 500%,
725
level
9999
Auto Baudrate/Max
726
0 to 255
Master
727
Max Info Frames
1 to 255
Device instance
728
number (Upper 3 digits) 0 to 419
Device instance
729
number (Lower 4 digits) 0 to 9999
Second motor induced
0 to 5000mV/
738
voltage constant (phi f)
(rad/s), 9999
Second motor Ld decay
0 to 100%,
739
ratio
9999
Second motor Lq decay
0 to 100%,
740
ratio
9999
Second starting resistance
0 to 200%,
741
tuning compensation
9999
Second motor magnetic
0 to 6000μs,
742
pole detection pulse
10000 to
width
16000μs, 9999
Second motor
0 to 400Hz,
743
maximum frequency
9999
Second motor inertia
10 to 999,
744
(integer)
9999
Second motor inertia
745
0 to 7, 9999
(exponent)
Second motor
100 to 500%,
746
protection current level
9999
0, 10, 11, 20,
21, 50, 51, 60,
61, 70, 71, 80,
81, 90, 91,
Second PID action
753
100, 101,
selection
1000, 1001,
1010, 1011,
2000, 2001,
2010, 2011
Second PID control
0 to 590Hz,
754
automatic switchover
9999
frequency
Second PID action set
0 to 100%,
755
point
9999
Second PID
0.1 to 1000%,
756
proportional band
9999
Second PID integral
0.1 to 3600s,
757
time
9999
Second PID differential
0.01 to 10.00s,
758
time
9999
759
PID unit selection
0 to 43, 9999
760
Pre-charge fault selection 0, 1
761
Pre-charge ending level 0 to 100%, 9999 9999
762
Pre-charge ending time 0 to 3600s, 9999 9999
Pre-charge upper
0 to 100%,
763
detection level
9999
764
Pre-charge time limit
0 to 3600s, 9999 9999
Second pre-charge
765
0, 1
fault selection
Second pre-charge
0 to 100%,
766
ending level
9999
Second pre-charge
0 to 3600s,
767
ending time
9999
Second pre-charge
0 to 100%,
768
upper detection level
9999
Second pre-charge
0 to 3600s,
769
time limit
9999
1 to 3, 5 to 14,
Operation panel
774
17, 18, 20,
monitor selection 1
23 to 25, 34, 38,
Operation panel
40 to 45,
775
monitor selection 2
50 to 57, 61, 62,
64, 67 to 69,
Operation panel
81 to 96,
776
monitor selection 3
98,100, 9999
4 mA input check
0 to 590Hz,
777
operation frequency
9999
778
4 mA input check filter
0 to 10s
Setting
Initial
range
value
100%
9999
100%
9999
9999
9999
9999
9999
9999
9999
255
1
0
0
9999
9999
9999
9999
9999
9999
9999
9999
9999
0
9999
9999
100%
1s
9999
9999
0
9999
0
9999
9999
9999
9999
9999
9999
9999
9999
0s