Setting
Pr.
Name
range
Operation frequency
0 to 590Hz,
779
during communication
9999
error
Acceleration time in
0 to 3600s,
791
low-speed range
9999
Deceleration time in
0 to 3600s,
792
low-speed range
9999
Pulse increment setting
0.1, 1, 10, 100,
799
for output power
1000kWh
800
Control method selection 9, 20
820
Speed control P gain 1 0 to 1000%
Speed control integral
821
0 to 20s
time 1
822
Speed setting filter 1
0 to 5s, 9999
Torque control P gain 1
824
(current loop
0 to 500%
proportional gain)
Torque control integral
825
time 1 (current loop
0 to 500ms
integral time)
827
Torque detection filter 1 0 to 0.1s
828
Parameter for manufacturer setting. Do not set.
0 to 1000%,
830
Speed control P gain 2
9999
Speed control integral
831
0 to 20s, 9999 9999
time 2
832
Speed setting filter 2
0 to 5s, 9999
834
Torque control P gain 2 0 to 500%, 9999 9999
Torque control integral
0 to 500ms,
835
time 2
9999
837
Torque detection filter 2 0 to 0.1s, 9999 9999
Analog input offset
849
0 to 200%
adjustment
Terminal 4 function
858
0, 4, 9999
assignment
0 to 500A,
9999

Torque current/Rated
859
PM motor current
0 to 3600A,
9999

0 to 500A,
Second motor torque
9999

860
current/Rated PM
0 to 3600A,
motor current
9999

864
Torque detection
0 to 400%
Torque monitoring
866
0 to 400%
reference
867
AM output filter
0 to 5s
Terminal 1 function
868
0, 4, 9999
assignment
869
Current output filter
0 to 5s

Speed detection
870
0 to 5Hz
hysteresis
Input phase loss
872
0, 1
protection selection
874
OLT level setting
0 to 400%
Regeneration
882
avoidance operation
0 to 2
selection
Regeneration
883
avoidance operation
300 to 800V
level
Regeneration avoidance
884
at deceleration detection
0 to 5
sensitivity
Regeneration avoidance
0 to 590Hz,
885
compensation frequency
9999
limit value
Regeneration
886
0 to 200%
avoidance voltage gain
888
Free parameter 1
0 to 9999
889
Free parameter 2
0 to 9999
Cumulative power monitor
891
0 to 4, 9999
digit shifted times
892
Load factor
30 to 150%
0.1 to 55kW
Energy saving monitor
893
reference (motor
capacity)
0 to 3600kW
Control selection during
894
commercial power-
0 to 3
supply operation
Power saving rate
895
0, 1, 9999
reference value
896
Power unit cost
0 to 500, 9999 9999
Power saving monitor
0, 1 to 1000h,
897
average time
9999
Power saving cumulative
898
0, 1, 10, 9999 9999
monitor clear
Operation time rate
0 to 100%,
899
(estimated value)
9999
C0
FM/CA terminal
(900)
calibration


C1
AM terminal calibration ―
(901)

C2
Terminal 2 frequency
0 to 590Hz
(902)
setting bias frequency

Initial
Pr.
Name
value
C3
Terminal 2 frequency
9999
(902)
setting bias

125
Terminal 2 frequency
(903)
setting gain frequency

9999
C4
Terminal 2 frequency
(903)
setting gain

9999
C5
Terminal 4 frequency
(904)
setting bias frequency

1kWh
C6
Terminal 4 frequency
20
(904)
setting bias

25%
126
Terminal 4 frequency
(905)
setting gain frequency

0.333s
C7
Terminal 4 frequency
(905)
setting gain

9999
C12
Terminal 1 bias
(917)
frequency (speed)

50%
C13
Terminal 1 bias (speed) 0 to 300%
(917)

40ms
C14
Terminal 1 gain
(918)
frequency (speed)

0s
C15
Terminal 1 gain (speed) 0 to 300%
(918)

C16
Terminal 1 bias command
9999
(919)
(torque/magnetic flux)

C17
Terminal 1 bias (torque/
(919)
magnetic flux)

C18
Terminal 1 gain command
9999
(920)
(torque/magnetic flux)

C19
Terminal 1 gain (torque/
(920)
magnetic flux)

9999
C8
Current output bias
(930)
signal

100%
C9
Current output bias
(930)
current
0

C10
Current output gain
(931)
signal

9999
C11
Current output gain
(931)
current

C38
Terminal 4 bias command
9999
(932)
(torque/magnetic flux)

C39
150%
Terminal 4 bias (torque/
(932)
magnetic flux)

150%
C40
Terminal 4 gain command
0.01s
(933)
(torque/magnetic flux)

0
C41
Terminal 4 gain (torque/
(933)
0.02s
magnetic flux)

0Hz
C42
PID display bias
(934)
coefficient

0
C43
PID display bias analog
120/110%

(934)
value

0
C44
PID display gain
(935)
coefficient

C45
PID display gain analog
DC380/
(935)
value

DC760V

Input voltage mode
977
selection
0
Parameter copy alarm
989
release
6Hz
990
PU buzzer control
991
PU contrast adjustment 0 to 63
100%
9999
Operation panel setting
992
dial push monitor
9999
selection
9999
100%
997
Fault initiation
Inverter

LD/SLD
PM parameter
998

rated
initialization

capacity

Automatic parameter
999

setting
0
1000
Direct setting selection 0 to 2
Lq tuning target current
9999
1002
adjustment coefficient
1006
Clock (year)
9999
9999
1007
Clock (month, day)
0Hz
Setting
Initial
Pr.
range
value
0 to 300%
0%
0 to 590Hz
60/50Hz

0 to 300%
100%
0 to 590Hz
0Hz
0 to 300%
20%
1008
Clock (hour, minute)
0 to 590Hz
60/50Hz

0 to 300%
100%
0 to 590Hz
0Hz
0%
0 to 590Hz
60/50Hz

Running speed after
100%
1013
emergency drive retry
reset
0 to 400%
0%
Integral stop selection
1015
at limited frequency
0 to 300%
0%
PTC thermistor
1016
protection detection time
0 to 400%
150%
Monitor with sign
1018
selection
0 to 300%
100%
1020
Trace operation selection 0 to 4
1021
Trace mode selection
0 to 100%
0%
1022
Sampling cycle
Number of analog
1023
channels
0 to 100%
0%
1024
Sampling auto start
1025
Trigger mode selection 0 to 4
0 to 100%
100%
Number of sampling
1026
before trigger
0 to 100%
100%
Analog source selection
1027
(1ch)
Analog source selection
1028
0 to 400%
0%
(2ch)
Analog source selection
1029
(3ch)
0 to 300%
20%
Analog source selection
1030
(4ch)
Analog source selection
0 to 400%
150%
1031
(5ch)
Analog source selection
1032
(6ch)
0 to 300%
100%
Analog source selection
1033
(7ch)
0 to 500.00,
9999
Analog source selection
9999
1034
(8ch)
1035
Analog trigger channel 1 to 8
0 to 300%
20%
Analog trigger
1036
operation selection
0 to 500.00,
9999
1037
Analog trigger level
9999
Digital source selection
1038
0 to 300%
100%
(1ch)
Digital source selection
1039
0, 1
0
(2ch)
Digital source selection
10
10
1040


(3ch)
100
100


Digital source selection
1041
0, 1
1
(4ch)
58
Digital source selection
1042
(5ch)
0 to 3, 5 to 14,
17, 18, 20,
Digital source selection
1043
23 to 25, 34, 38,
(6ch)
40 to 45,
0
Digital source selection
50 to 57, 61, 62,
1044
(7ch)
64, 67 to 69,
Digital source selection
81 to 96, 98,100
1045
(8ch)
0 to 255, 9999 9999
1046
Digital trigger channel
0, 12, 14, 112,
Digital trigger operation
114, 8009,
1047
0
8109, 9009,
selection
9109
1048
Display-off waiting time 0 to 60min
1, 2,10 to 13,
1049
USB host reset
9999
20, 21, 9999
1106
Torque monitor filter
0
Running speed monitor
1107
50 to 150%,
filter
9999
9999
Excitation current
1108
2000 to 2099
2000
monitor filter
101 to 131,
Station number in
1124
201 to 229,
inverter-to-inverter link
301 to 331,
Number of inverters in
401 to 430,
1125
inverter-to-inverter link
501 to 531,
system
601 to 630,
101
701 to 731,
Pre-charge change
1132
801 to 831,
increment amount
901 to 930,
Second pre-charge
1001 to 1031,
1133
change increment amount
1101 to 1130,
1201 to 1231
Second PID display
1136
bias coefficient
Parameter list
Setting
Initial
Name
range
value
0 to 59,
100 to 159,
200 to 259,
300 to 359,
400 to 459,
500 to 559,
600 to 659,
700 to 759,
800 to 859,
900 to 959,
1000 to 1059,
1100 to 1159,
0
1200 to 1259,
1300 to 1359,
1400 to 1459,
1500 to 1559,
1600 to 1659,
1700 to 1759,
1800 to 1859,
1900 to 1959,
2000 to 2059,
2100 to 2159,
2200 to 2259,
2300 to 2359
0 to 590Hz
60/50Hz

0, 1, 10, 11
0
0 to 60s
0s
0, 9999
9999
0
0 to 2
0
0 to 9
2
1 to 8
4
0, 1
0
0
0 to 100%
90%
201
202
1 to 3, 5 to 14,
203
17, 18, 20, 23,
24, 34,
40 to 42,
204
52 to 54, 61,
62, 64, 67, 68,
205
81 to 96, 98,
201 to 213,
230 to 232,
206
237, 238
207
208
1
0, 1
0
600 to 1400
1000
1
2
3
4
1 to 255
5
6
7
8
1 to 8
1
0, 1
0
0min
0, 1
0
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5s, 9999
9999
0 to 5, 9999
9999
2 to 6
2
0 to 100%,
9999
9999
0 to 100%,
9999
9999
0 to 500, 9999 9999
21
BASIC OPERATION