SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
Termination: Automatic, 75Ω, or Hi-Z if looped
Display memory: 1024 X 1024 memory array, 8 Mb total display memory
Resolution: 720 pixels, Horizontal, 484 active lines Vertical (576 CCIR)
Grey Scale: 256 levels
Alarm Handling:
Alarm inputs: 16. Programmable NO or NC in menus.
Alarm outputs: Two (2), form C relays, each NO and NC.
Alarm latching: Three (3) settings: Latched; Transparent; Timed-out, programmable 1 - 100 seconds
Alarm recording: Automatic priority control, interleaved or exclusive, or none, programmable.
Alarm Displays: Automatic full-screen
Controls and Indicators:
RECORD: Selects record mode. On duplex model, always in record mode. This key inactive.
Indicator: RECORD mode, LED.
PLAY: Selects playback mode for decoding tapes.
LIVE: Selects LIVE mode
SEQUENCE: Starts or stops sequencing. Operates on multi-screen displays and full-screen displays.
Selectable dwell and Autolists, on-screen indicator
MACRO FUNCTION: {F} Starts execution of a pre-recorded key sequence. Sixteen macros can be
recorded by the user.
ALARM: Used to accept active alarms
ALARM INDICATORS: LED flashes on any active alarm; plus buzzer
FREEZE: Freezes any display in LIVE or PLAY mode.
ZOOM: Zooms 2x, fully interlaced, on full-screen displays
PAN & TILT: Arrow keys provide digital pan & tilt on zoomed images.
MULTISCREEN: Selects multi-screen displays in LIVE or PLAY mode. Toggles through list of multi-
screens.
1 - 16 Selects corresponding camera, full-screen
ARROWS: Used in menus, and Pan & Tilt.
MENU SETUP: Enters and exits menu screens for programming of unit. Password protected.
ENTER: Selects menu items when programming. Starts active cameo mode, LED lit in active cameo
mode
TIME and DATE: Displays time and date in selectable formats plus Summer/Winter time change
function.
Video Indicators:
Alarms, video loss, Record speed, Playback.
Titles: 12 characters, plus camera number, display can be turned off.
VCR View: The VCR can be selected as an input to aid VCR setup, using {F} key.
Motion Detection:
Zones per camera: 256, 16 x 16 grid
Sensitivity settings: 10 levels
Grey levels per zone: 256 levels
Recording Priority: 2x, 4x, interleaved, or none
Status Output: RS-232 status. Relays, link to alarms
Remote Control and Programming:
RS-232: D-sub9, female. 3-wire, N-8-1. 9600baud. Allows remote programming of menus, upload of status
data, remote control of front panel buttons
RS-485: RJ-45 remote keyboard input, looping, up to 1000m (3,200') without conditioning.
JVC PROFESSIONAL, IMAGING PRODUCTS
Rated 0.5A continuous, 1.0 A momentary.