Mitsubishi Electric AE630-SW Instruction Manual page 27

Low-voltage air circuit breakers type ae, modbus interface unit bif-md
Hide thumbs Also See for AE630-SW:
Table of Contents

Advertisement

Table 5.6.13 analog measurement 2 register
Address
Number
Access
of bytes
Dec. Hex.
812 032Ch
2
R
Max. instantaneous current in Phase 1 (I1) *1
813 032Dh
2
R
Max. instantaneous current in Phase 2 (I2) *1
814 032Eh
2
R
Max. instantaneous current in Phase 3 (I3) *1
815 032Fh
2
R
Max. instantaneous current in Pole N (IN) *1
816 0330h
2
R
Reserved
817 0331h
2
R
Max. demand current in Phase 1 (I1) *1
818 0332h
2
R
Max. demand current in Phase 2 (I2) *1
819 0333h
2
R
Max. demand current in Phase 3 (I3) *1
820 0334h
2
R
Max. demand current in Pole N (IN) *1
821 0335h
2
R
Reserved
822 0336h
2
R
Max. demand current in Max. Phase
823 0337h
2
R
Max. instantaneous voltage in Line 1-2 (V12)
824 0338h
2
R
Max. instantaneous voltage in Line 2-3 (V23)
825 0339h
2
R
Max. instantaneous voltage in Line 1-3 (V13)
826 033Ah
2
R
Reserved
827 033Bh
2
R
Max. instantaneous voltage in Max. Line
828 033Ch
2
R
Max. instantaneous voltage in Phase 1-N (V1N)
829 033Dh
2
R
Max. instantaneous voltage in Phase 2-N (V2N)
830 033Eh
2
R
Max. instantaneous voltage in Phase 3-N (V1N)
831 033Fh
2
R
Reserved
832 0340h
2
R
Max. instantaneous voltage in Max. Phase
833 0341h
2
R
Reserved
834 0342h
2
R
Reserved
835 0343h
2
R
Reserved
836 0344h
2
R
Max. instantaneous power Factor *5
837 0345h
2
R
Reserved
838 0346h
2
R
Reserved
839 0347h
2
R
Reserved
840 0348h
2
R
Reserved
841 0349h
2
R
Max. instantaneous active power *5
842 034Ah
2
R
Reserved
843 034Bh
2
R
Reserved
844 034Ch
2
R
Reserved
845 034Dh
2
R
Max. demand active power *5
846 034Eh
2
R
Reserved
847 034Fh
2
R
Reserved
848 0350h
2
R
Reserved
849 0351h
2
R
Max. instantaneous reactive power *5
850 0352h
2
R
Reserved
851 0353h
2
R
Reserved
852 0354h
2
R
Reserved
853 0355h
2
R
Max. instantaneous apparent power
854 0356h
2
R
Max. demand reactive power *5
855 0357h
2
R
Max. demand apparent power
856 0358h
2
R
Max. instantaneous earth leakage(Ig) *1,6
857 0359h
2
R
Max. demand earth leakage (Ig) *1,6
*1 Only data of current (from 32Ch to 336h) and earth leakage (0358h, 0359h) can be monitored without VT unit.
*2 In case of 3φ3W, N Pole measurements ( 32Fh, 334h, 33Ch to 33Eh) can not be monitored.
*3 In case of "In=250 to 315", Unit: 0.1A. In case of "In=500 to 6300", Unit: 1A.
*4 In case of "In=250 to 630", Unit: 0.1kW, 0.1kvar, 0.1kVA. In case of "In=1000 to 6300", Unit: 1kW, 1kvar, 1kVA.
*5 Minus data is expressed as two's complement.
*6 Earth leakage (0358h, 0359h) can not be monitored without E1 module.
*All max. items are saved in EEPROM of EX1 module every 2 hours.