Requirements for Cable Routing
Installing Power Adapters
Installing the OT Terminal
Procedure
1.
Issue 02 (2015-05-18)
To protect cables, remove the burrs in the cable through-holes or install protective rings
in the holes.
To ease the connection and to avoid stress, keep slack at cable joints. After connecting
multiple cables to a connector that has multiple interfaces, keep the cables slack to avoid
stress generation.
Bind or clean cables gently because cable distortion affects signal quality.
Keep cables away from moveable components such as doors.
Sharp objects must not be touched in cable wiring to ensure that cables are not damaged.
To protect power cables, power cables of the active and standby power modules are laid
separately.
Install an OT terminal.
Align the hole of the OT terminal (conductor upward) with a connecting hole, as shown
in
Figure
5-42.
Figure 5-42 Aligning the OT terminal with a connecting hole
When you install an OT terminal, the crimping sleeve is installed as shown in
correct and B is wrong.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
5 Appendix
Figure
5-43, where A is
48