(10) 10BASE-T/100BASE-TX/1000BASE-T Interface Cable (CAT.5E,RJ45 connector)
The boundary with 10BASE-T, 100BASE-TX and 1000BASE-T is the connector on
GR4000. For the connection with 1000BASE-T, use a UTP interface cable categorized as
"Enhanced Category 5". (It is possible to use a UTP interface cable categorized as
"Category 5" for the connection only with 100BASE-TX. Also, it is possible to use a UTP
interface cable categorized "Category 3" for the connection only with 10BASE-T.)
The maximum transmission distance for the connection of GR4000 with 10BASE-T,
100BASE-TX or 1000BASE-T is 100m.
Figure 3.2-11 below shows the rough sketch of the cable , and Table 3.2-16 shows the
pin arrangement on GR4000.
RJ45 connector
Figure 3.2-11 Rough Sketch of Twist Pair Cable (CAT.5E)
Table 3.2-16 Pin Arrangement on the GR4000 (for 10BASE-T/100BASE-TX/1000BASE-T
Pin number
Specification
1
Transmit A(+)
2
Transmit A(-)
3
Transmit B(+)
4
Transmit C(+)(Note 1) (C)
5
Transmit C(-)(Note 1) (c)
6
Transmit B(-)
7
Transmit D(+)(Note 1) (D)
8
Transmit D(-)(Note 1) (d)
(Note 1)
:
This should be connected to the port when using 1000BASE-T.
(Note 2)
:
Because the interface uses differential, twisted pairs of wires, make (A) and (a), (B) and (b), (C) and (c), and (D) and (d) into pairs
when using 1000BASE-T.
520-10-014-20X
interfaces)
(A)
(a)
(B)
(b)