V O L T S / D S V Control
Vertical attenuator for channel 1 . Provides step adjust-
ment of vertical sensitivity in 1-2-5 sequence.
A B L E control
is turned to the C A L position, the
calibrated vertical sensitivity is obtained.
operation, this control serves as the attenuator
Y axis.
@
V A R I A B L E / P U L L X 5 G A I N Controls
V A R I A B L E :
Rotation provides fine control of C H 1 vertical sensi-
tivity.
In the fully clockwise ( C A L ) position, the
vertical attenuator is calibrated. For X - Y operation,
this control serves for X-axis attenuation fine adjust-
ment.
P U L L X 5 G A I N :
When pulled out, the V O L T S / D I V setting is multiplied
by five, and for X - Y operation, the X-axis sensitivity
is multiplied accordingly. In X 5 G A I N mode, increas-
ed vertical gain makes the trace thiker.
@
y POSITION Control
Rotation adjusts vertical position of C H 1 waveform on
the screen. For X - Y operation, this control adjusts Y
axis position.
In memory scope operation, the control provides D C
O F F S E T adjustment of C H 1 , superimposing the D C
level over input signal.
Clockwise rotation of the control adds +DC level to the
G N D level. Counterclockwise rotation adds - D C level
to the G N D level.
8
Fig. 2
@
y M E M O R Y POSITION Control
Adjusts the vertical position of the stored waveform.
With selection of the S A M P L I N G C L O C K A Control,
V A R I -
this control adjusts the vertical position of the stored
waveform. For memory operation in X - Y mode, the
For X - Y
control adjusts Y - a x i s position.
for
N O T E :
T h i s control has no effect on M E M O R Y O U T A @
@
INPUT Jack
Receives C H 2 vertical input, or X-axis input in X - Y
operation.
©
AC-GND-DC Switch
Selects the coupling of channel 2 vertical input signal.
In X - Y operation, the switch provides input selection
of X-axis and performs the same function as A C - G N D -
D C ® for C H 1 .
@
V O L T S / D I V Control
Vertical attenuator for C H 2 . Provides the same func-
tion as V O L T S / D I V Control ©
operation, the control serves as the X-axis attenuator.
@
V A R I A B L E / P U L L X 5 GAIN Control
Provides the fine control of the vertical attenuation for
C H 2 and increases the vertical sensitivity. The control
performs the same function as V A R I A B L E / P U L L X 5
G A I N Control ( R ) for C H 1 . In X - Y operation, the
control
attenuation and increases the X-axis sensitivity.
for C H 1 . In X - Y
provides the fine adjustment of the X-axis
jack.