Appendix 1.14 Grounding Plate and Clamp Fitting Outline Drawings

Appendix 1.14 Grounding Plate and Clamp Fitting Outline Drawings
The shield wire generally only needs to
be grounded to the connector's case
frame. However, the effect can be
improved by directly grounding to the
grounding plate as shown on the right.
Install the grounding plate near each
unit. Peel part of the cable sheath as
shown on the right to expose the shield
sheath. Press that section against the
grounding plate with the clamp fitting.
Note that if the cable is thin, several
can be clamped together.
Install the grounding plate directly onto
the cabinet or connect a grounding
wire so that sufficient frame grounding
is achieved.
If the AERSBAN-SET, containing the
grounding plate and clamp fitting, is
required, please contact Mitsubishi.
• Outline drawing
Grounding plate
2- φ 5 hole
Installation hole
Note 1) M4 screw
Note 1) Screw hole for wiring to cabinet's grounding plate
Note 2) The grounding plate thickness is 1.6mm
AERSBAN-DSET
AERSBAN-ESET
APPENDIX 1 INSTALLATION DIMENSIONS
17.5
22
6
35
A
B
C
100
86
30
Two clamp fittings A
70
56
One clamp fitting B
Clamp fitting
(F itting A, B)
Shield sheath
Clamp fitting
MAX L
10
Enclosed fittings
105
Cable
Grounding plate
Clamp section drawing
Clamp fitting A
Clamp fitting B
L
70
45

Advertisement