CHAPTER 6 CONNECTION OF REMOTE I/O UNIT

This chapter describes the connection of the remote I/O unit and machine control signals.

6.1 Outline of Remote I/O Unit

The following eight types of signals can be input/output from the remote I/O unit (FCUA-DX
according to the type and No. of contacts. Use serial link connections (MC link B) to connect the unit with
the control unit or the communication terminal.
When the remote I/O unit is connected with serial links, multiple units can be used as long as the total No.
of occupied channels is within 8 channels. (Refer to "Section 6.14 Setting the Channel No. for
Connecting Multiple Remote I/O Units" for details.)
Unit name
Digital input signal (DI)
FCUA-DX100
Digital output signal (DO) : 32 points (non-insulation) sink type
Digital input signal (DI)
FCUA-DX101
Digital output signal (DO) : 32 points (non-insulation) source type
Digital input signal (DI)
FCUA-DX110
Digital output signal (DO) : 48 points (non-insulation) sink type
Digital input signal (DI)
FCUA-DX111
Digital output signal (DO) : 32 points (non-insulation) source type
Digital input signal (DI)
FCUA-DX120
Digital output signal (DO) : 48 points (non-insulation) sink type
Analog output (AO)
Digital input signal (DI)
FCUA-DX121
Digital output signal (DO) : 48 points (non-insulation) source type
Analog output (AO)
Digital input signal (DI)
FCUA-DX130
Digital output signal (DO) : 32 points (non-insulation) sink type
Handle input (AO)
Digital input signal (DI)
FCUA-DX131
Digital output signal (DO) : 32 points (non-insulation) source type
Handle input (AO)
Digital input signal (DI)
Digital output signal (DO) : 32 points (non-insulation) sink type
FCUA-DX140
Analog input (AI)
Analog output (AO)
Digital input signal (DI)
Digital output signal (DO) : 32 points (non-insulation) source type
FCUA-DX141
Analog input (AI)
Analog output (AO)
CHAPTER 6 CONNECTION OF REMOTE I/O UNIT
6.1 Outline of Remote I/O Unit
Machine control signals that can be handled
: 32 points (photo coupler insulation) sink/source type
: 32 points (photo coupler insulation) sink/source type
: 64 points (photo coupler insulation) sink/source type
: F64 points (photo coupler insulation) sink/source type
: 64 points (photo coupler insulation) sink/source type
: 1 point
: 64 points (photo coupler insulation) sink/source type
: 1 point
: 32 points (photo coupler insulation) sink/source type
: 2 pieces
: 32 points (photo coupler insulation) sink/source type
: 2 pieces
: 32 points (photo coupler insulation) sink/source type
: 4 points
: 1 point
: 32 points (photo coupler insulation) sink/source type
: 4 points
: 1 point
73
)
No. of occupied
serial link channels
1
1
2
2
2
2
2
2
2
2