Cable Type Name: Sh21 Cable (Servo Amplifier); Appendix 2.1; Cable Type Name: Sh41 Cable (Remote I/O) - Mitsubishi Electric MELDAS 600 Series Connection Manual

Hide thumbs Also See for MELDAS 600 Series:
Table of Contents

Advertisement

Cable type name: SH21 cable Usage: Servo amplifier
Connector name : SV1, SV2 (CSH21)
SV1, SV2 (CSH21)
Plug : 10120-6000EL
Shell : 10320-3210-000
Recommended maker: Sumitomo 3M
Note:
Cable type name: SH41 cable Usage: Remote I/O
Connector name : RIO1, RIO2, RIO3 (CSH41)
RIO1,RIO2,RIO3(CSH41)
RIO1, RIO2, RIO3 (CSH41)
Connector : 1-178288-3
Contact
: 1-175218-2
Recommended maker: Japan AMP
Note
1. Protect both side of cable by isolated bush.
2. RIO1, RIO2, RIO3 can be used as common.
3. Use this cable if the cable length is short such as when bridging between remote I/O units in the same panel.
Normally, use the FCUA-R11 cable having a high noise resistance level.
APPENDIX 2 CABLE MANUFACTURING DRAWINGS
Wire material: UL20276 AWG28 × 10P
Recommended maker: Toyokuni Densen
Fold the wire material shield over the sheath, and wrap copper foil tape over it.
Clamp with the connector case GND plate.
TXRX
1
TXRX∗
2
GND
3
Wire material: MVVS 3C×0.3SQ (MIC 3C×0.3SQ)
Recommended maker: Takeuchi Densen
Servo amplifier
Plug : 10120-6000EL
Shell : 10320-3210-000
Recommended maker: Sumitomo 3M
Connector name : (CSH41)
(CSH41)
1
2
3
107

Appendix 2.1

Appendix 2.2
TXRX
TXRX∗
GND
(CSH41)
Connector : 1-178288-3
Contact
: 1-175218-5
Recommended maker: Japan AMP