RF Module

Chapter 7 - Replacing Parts
Removing the Hexagonal Screws
6. Remove 4 screws.
7. Lift out Processor Board.
To replace the Processor Board:
1. Replace the 4 screws which hold the Processor board and tighten them
(not completely) so the board can still move.
2. Replace the 2 hexagonal screws (E) at back of monitor, screwing them
in tightly.
3. Tighten the 4 screws so the Processor board is held firmly.
4. Reconnect and tighten the coax cable with M6 spanner.
5. Reconnect all cables.
To remove the RF Module, first follow the instructions for dismantling the
Receiver, then:
1. Disconnect the flat cable (B).
2. Remove the coax cable from the Receiver Board Assembly with M6
spanner (A).
3. Lift the Receiver Board Assembly clear of the casing (C).
Power Supply Board