Asus ISDNLINK TA-200 Manual page 6

Table of Contents

Advertisement

Terminator setup of ISDNL
2.
*
Please jump to the next section (3.) if you are the user of U interface terminal
adapter, TA-200U or TA-200U-D.
The ISDN S/T interface can support up to 8 ISDN terminals and through a single
NT1 device for connection to the ISDN line. Only one ISDN S/T device should
have the terminator enabled. This is normally the ISDN terminal, which is the
furthest from NT1.
The ISDNL
INK ™
DIP switches on the back of the device for the terminator setup. The default
setting of ISDNL
DIP switch are set to "ON"). If there is any other ISDN device connected to the
NT1, and you do not require ISDNL
switch "1" and "2" to "OFF".
Analog device connection
3.
The TA-200ST (TA-200U) supports a/b (POTS) connection through RJ-11 jack
(adapters supplied in the UK). You can use this POTS port to connect to standard
analog phone devices.
analog devices to be simultaneously connected.
analog telephone set, G3 fax, modem, or answering machine directly on the TA
back plane or through RJ-11 extension cable with the standard RJ-11 connection.
In the UK an adapter is supplied to convert from the UK type 103 plug to the US
RJ-11 plug.
ring number is 3 for a/b analog interface connection
ISDN connection
4.
Connect the ISDNL
and connect the other end of the cable to the ISDN BRI line NT1 socket.
OR
If you have the U interface models (not in Europe) directly insert the RJ-45
connector cable into the ISDN BRI line and the other end of the cable into the RJ-
45 jack on the ISDNL
45 connector has 8 pins and RJ-11 has 4 or 6 pins you can still plug the cable from
the wall jack with RJ-11 connector into RJ-45 jack on the ISDNL
TA.
Please note that the POTS analogue ports on the TA200 device, in common with most PBX, terminal
2
adapters and fax switches, supply a reduced ring voltage. That is to say the ring voltage is lower than
that provided on a standard PSTN phone line. This does mean that in very rare circumstances some
analogue equipment may not be able to detect an incoming call.
6
INK ™
ST interface terminal adapters (TA-200ST and TA-200ST-D) have
TA is with the terminator enabled (The positions "1" and "2" of
INK ™
The RJ-11 extension cable supplied allows for two
The REN (Ringer Equivalence Number) drive capability or parallel
S/T interface TA and NT1 with the RJ-45 cable supplied
INK ™
U interface TA. Please note that even though the RJ-
INK ™
© COPYRIGHT OF ASUSCOM NETWORK INC.
"ST" interface terminal adapter
TA as terminator, then please set the DIP
INK ™
2
Users can connect the
.
INK™
U interface

Advertisement

Table of Contents
loading