Error Messages During File Transfers - GE MDS iNET Series Reference Manual

Wireless ip/ethernet transceiver
Hide thumbs Also See for MDS iNET Series:
Table of Contents

Advertisement

NOTE:
The
LAN
and
Transferring the radio firmware image file ( 3 Mb), may take several minutes depending on
traffic between the TFTP server and the transceiver.
Regardless of your connection to the transceiver, loading firmware/configuration files into the
unit's flash-RAM is much slower than loading software onto a PC hard drive or RAM.
Upgrade Procedure
To load a new firmware file (
1. Launch a TFTP server on a PC connected either directly or via a LAN to the Ethernet port (
radio. Point the server towards the directory containing the firmware image file.
2. Connect to the Management System by whichever means is convenient: Browser or Telnet via the
or Terminal emulator via the
3. Go to the Reprogramming Menu.
(Main Menu>>Maintenance/Tools Menu>>Reprogramming Menu)
4. Fill in the information for the:
TFTP Host Address
—Name of file (
Filename
5. Pull the firmware file through the TFTP server into the transceiver.
(Main Menu>>Maintenance/Tools Menu>>Reprogramming Menu>>Retrieve File)
Status messages on the transfer are posted on the Management System screen.
NOTE:
The new firmware image file that replaces the "Inactive Image" file will be automatically veri-
fied.
6. Reboot the transceiver.
Main Menu>>Maintenance/Tools Menu>>Reprogramming Menu>>Reboot Device
7. Test the transceiver for normal operation.
End of Procedure
NOTE:
During a reprogramming session, functional operation and services will be limited. Allow the unit
to finish the reprogramming session before using any management interfaces.

Error Messages During File Transfers

It is possible to encounter errors during a file transfer. In most cases errors can be quickly corrected by refer-
ring to Table 2-8.
Error Message
Invalid File Type
File not found
Invalid file path
86
COM1
ports share a common data channel when loading firmware over-the-air.
) into the transceiver, use the following procedure:
filename.ipk
COM1
port.
—IP Address of server (host computer) running TFTP server.
to be pulled from the TFTP server holding the firmware file.
filename.ipk)
Table 2-8. Common Errors During TFTP Transfer
MDS iNET Series Reference Manual
Likely Cause/Corrective Action
Indicates that the file is not a valid firmware
file. Locate proper file and re-load.
Invalid or non-existent filename on TFTP
server
Invalid or non-existent file path to TFTP server
) of the
LAN
,
LAN