Installation
Installing in a Rack
4
Attach the shelf plate to the AC sensor unit.
Use two M4 cross recessed head screws with captive washer to attach the shelf plate to the AC sensor unit.
M4 cross recessed head screws with captive washer
Up to two AC sensor units can be attached to the same shelf plate. Attach the first AC sensor unit on
the right side when facing the shelf plate as shown in the figure above.
5
Attach the shelf plate to the rack.
Use four M6 cross recessed head screws with captive washer to fasten the shelf plate in the rack.
M6 cross recessed head screws
with captive washer
FUJITSU Storage ETERNUS AF, ETERNUS DX Configuration Guide (Power Synchronized Unit)
Shelf plate
(Rear rack pillars)
M6 cross recessed head screws
with captive washer
40
Copyright 2019 FUJITSU LIMITED
P3AM-8012-14ENZ0