* USB cable Type B connector - Type A connector
Note
Possible number of extended versions or PRO devices on a PC
A free USB interface and a free DisplayPort interface of the PC are required for each direct
connection of an extended version or PRO device to a PC. This means that the possible
number of IFPs on a PC is defined by the number of available USB and DisplayPort interfaces
of the PC.
Possible number of PCs on an extended version or a PRO device
As soon as the DisplayPort interface of the extended version or the PRO device is connected
to a PC, no video signals can be transmitted via the Ext-Link interface of the IFP. This means
that exactly one PC can be connected to one extended version or one PRO device.
Extended mode from 5 m to 100 m distance
Connect an extended version or a PRO device for longer distances up to 100 m to the PC via
the Transceiver Unit and the following cables:
Connection of extended version or PRO device to the Transceiver Unit
• A Cat. 6A Ethernet cable up to a maximum of 100 m in length
A direct connection via this cable is required, the connection cannot be extended via a
hub, switch or similar device.
Connection Transceiver Unit to the PC
• DisplayPort cable, length < 3 m
• USB cable, length < 3 m
Ferrites
In extended mode, 2 ferrites are connected to the ends of the Cat. 6A Ethernet cable
required. Mount the two supplied ferrites according to the following figure on the Cat. 6A
Ethernet cable.
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE
Installing and connecting the device
3.5 Connecting the device
65