Installing and connecting the device
3.6 Removing the device
3.6.3

Removing Transceiver Unit

The Transceiver Unit is generally removed in the reverse order for mounting and connecting.
Procedure
1. Switch off power supply to the Transceiver Unit.
2. When you use the Transceiver Unit in a hazardous area, make sure that one of the two
following requirements is met: The area is no longer hazardous or the Transceiver Unit and
its connectors are current-free.
3. Remove all cable ties from the strain relief elements of the Transceiver Unit.
4. Remove all plugs from the Transceiver Unit.
5. Remove the Transceiver Unit as follows, depending on the type of mounting:
– Mounting onto standard rail: Press the Transceiver Unit upwards and remove the
– Wall mounting: Remove the fixing screws and remove the Transceiver Unit from the
See also
Mounting the Transceiver Unit (Page 54)
Connecting the device (Page 56)
74
Transceiver Unit from the standard mounting rail.
wall.
IFP V2, IFP V2 PRO, IFP V2 ETH
Operating Instructions, 03/2023, A5E46641410-AE