16. Test information
9397 750 09238
Product data
The dynamic characteristics of the analog I/O ports (D+ and D−) as listed in
were determined using the circuit shown in
D. U. T.
Fig 22. Load for D+/D−.
Rev. 08 — 20 December 2001
USB interface device with parallel bus
Figure
22.
1.5kΩ IS INTERNAL
TEST POINT
22Ω
15kΩ
© Koninklijke Philips Electronics N.V. 2001. All rights reserved.
PDIUSBD12
Table
16,
C
= 50pF
L
SV00849
28 of 35