TUNING
SERVICE
Enter the 6 digit code to proceed to settings.
Hydraulics
The following components can be adjusted:
C1-C4, C1/C2
Rotation
Outriggers/dozer blade
Track L
Track R
Tool
Boom pressure
Pressure calibration
The selection "Reset system settings" resets all values to
their basic setting.
Ramp up/down
Ramp adjusts the acceleration of the drive.
A high up-value means slow acceleration.
A low up-value means quick acceleration.
A high down-value means slow braking.
A low down-value means quick braking.
Max-/min current
Max./min. current indicates the current interval that
controls the prop. valve. A too high minimum value means
that the valve opens rapidly. This might mean that it is not
possible to employ a function gently.
A low minimum value will increase the deadband of the
control lever around the central position.
A low maximum value means that the valve does not open
entirely and that the function cannot be run at maximum
speed.
A high maximum value means that the valve's maximum
opening position is achieved more rapidly. This will impair
resolution of the movement.
Boom pressure
The Boom pressure can be decreased from the
maximum 200 bar to 150 bar. The pressure changes with
5 bar intervals.
Machine types
Indicates which machine type the remote control is linked
to. This setting must be made when updating the software
or replacing the control module etc. Press the selection
key to confirm the choice.
SETTINGS
TUNING
1
3
Back
Enter code
_ _ _ _ _ _
2
4
OK
Languages
Setting for which language should be shown in the
display. Press the selection key to confirm the choice.
To return to the factory default language, english. Keep
the selection key for Work mode button while turning the
main switch until you see the main menu.
Joysticks
Settings for adjusting the function of the control levers.
Deadband
Deadband indicates the position in which the joysticks
start to be activated. The higher the value the farther out
from neutral position that the joysticks are activated.
Progression
Progression can be set from -100 to 100. A high value
gives increased resolution at low speeds. A low value
gives increased resolution at high speeds.
Mating Bluetooth®-radio modules
Used for remating the remote control with another
machine. During mating, the machine and the remote
control must be connected to each other by a cable.
Units
Setting of units for pressure and temperature that should
be shown in the display. Press the selection key to confirm
the choice.
Terminal diagnostics
Test menu for the functions in the terminal (remote
control). Joysticks, potentionmeters and pushbutton can
be tested.
SYSTEM INFORMATION
SERVICE
This shows the version of the software in the terminal and
the two control modules.
Hydraulics
Machine type
Languages
Terminal Diagnostics
Back
Joystick
Mating Bluetooth®