Cable/Sensor error
Message on the display
Cable to * has faulty circuit. Please
check cable.
Cable to * has feedback current
without control current. Please check
cable.
All warnings associated with ** are
disabled. Use machine with caution
*Cable error
Cylinder 1, valve
Cylinder 2, valve
Cylinder 3, valve
Cylinder 4, valve
Cylinder 5, valve
Outrigger proportional, valve
Left caterpillar track, valve
Right caterpillar track, valve
Rotation, valve
Tool, valve
Extra function 1, valve
Extra function 2, valve
Front left outrigger, valve
Front right outrigger, valve
Rear left outrigger, valve
Rear right outrigger, valve
Pressure, valve
**Sensor error
Temperature sensor
Pressure sensor
Oil level sensor
52 – English
TROUBLESHOOTING
Effect on
Indication on
machine
the machine
functions
The function
using the cable
disabled.
No indication on
machine.
All supervision
using the sensor
is disabled.
Cause
Possible action
The cable has a
short circuit or
broken circuit.
Check cable.
The cable * have
feedback current
without being
active.
Check the sensor *
Sensor ** is
and cables to the
faulty.
sensor.