Connecting A Normally Closed Alarm; Configuring An Open Collector Output - Bosch AutoDome 700 Series Installation Manual

Ip ptz camera
Hide thumbs Also See for AutoDome 700 Series:
Table of Contents

Advertisement

AutoDome 700 Series IP PTZ Camera
6.2.2

Connecting a Normally Closed Alarm

1.
2.
6.3

Configuring an Open Collector Output

The VG5 700 Series AutoDome incorporates one (1) open collector output.
This output must be connected to a positive voltage between 5 and 32 V to complete the
circuit, with a maximum voltage rating of 32 VDC @ 150 ma.
1.
2.
Bosch Security Systems, Inc.
Connect the alarm to the appropriate input (1 or 2) and ground at the AutoDome.
Figure 6.2 N.C. Normally Closed Non-supervised Connections
1
Dry Contact
2
Alarm Inputs 1 to 2
From the Alarm Connections page on the Settings Page (refer to the VG5 700 Series User
Manual) the Alarm Input # to N.C. See the table below for contact and condition details.
AutoDome Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Closed
Normal
Connect the appropriate stripped wire to the open connector (1, 2, or 3) of the
transistor.
Connect the appropriate stripped wire to the ground (GND) connector.
Installation Manual
3
Dome Connector
4
Ground
Alarms and Relay Connections | en
F.01U.215.779 | 1.0 | 2011.07
61

Advertisement

Table of Contents
loading

This manual is also suitable for:

Autodome vg5-724-ece2Autodome vg5-723-ece2