Installing/mounting
3.6 Disassembly
Procedure
1. Drill four holes into the wall.
The dimensions for the drill holes are specified in the drilling pattern that are specified on
drawings above.
2. Insert the anchors in the drilled holes (14mm).
3. Position the wall-mounted device on the wall and fasten it with the screws.
3.6

Disassembly

Incorrect disassembly
The following risks may result from incorrect disassembly:
- Injury through electric shock
- Risk through emerging media when connected to the process
- Risk of explosion in hazardous area
In order to disassemble correctly, observe the following:
• Before starting work, make sure that you have switched off all physical variables such as
• If the device contains hazardous media, it must be emptied prior to disassembly. Make sure
• Secure the remaining connections so that no damage can result if the process is started
36
WARNING
pressure, temperature, electricity etc. or that they have a harmless value.
that no environmentally hazardous media are released.
unintentionally.
SIPROCESS GA700 rack and wall mounted devices
Compact Operating Instructions, 06/2023, A5E35134047-AB